Special rotor shafts is something we get asked about frequently. Standard metric frame motors will have a standard IEC shaft from the factory, for example, a 71 frame machine will have a 14 x 30mm shaft. 80 frame will have 19 x 40mm and so on. This particular motor is quite unusual as it has […]
Category: Uncategorized

Helical Bevel Geared MotorHelical Bevel Geared Motor
This is one of our size 58 Helical Bevel Geared Motors with a 40mm diameter hollow output shaft, fitted with a 2.2Kw 4 pole TEC Electric Motor. It will be replacing a close coupled unit which failed overnight at a recycling plant. As the original motor had a shaft machined to suit a pinion the […]

Geared motors – check your oil levels !Geared motors – check your oil levels !
If you have geared motors running important and/or critical plant on your site please check your oil levels. Low oil levels and lack of maintenance can mean an expensive replacement is required.

Flygt sewage pump repairFlygt sewage pump repair
We where asked to investigate issues with this Flygt sewage pump which had stopped working. A test with the meter showed the unit had an earth fault. It was also seriously blocked with a rag and whatever else this used to be !!Please be mindful of what you put down the toilet !! This will […]

Deal Pier pump repairDeal Pier pump repair
Deal Pier stretches 313 meters out in to the English channel. Situated at the end of the Pier is a lovely little Restaurant (highly recommended) with toilet facilities (hence the reason for our visit!) Underneath the restaurant there is a very small building which houses 2 Mono pumps. These are responsible for pumping waste water […]

Weir Pump repairWeir Pump repair
This Weir pump came to us from one of the water authorities. Extensively corroded, it proved to be a bit of a challenge to get apart. Once it had been dismantled and all of the components shot blasted, we could see what needed doing.Some machining to the seal housings and a new extension shaft (made […]

Grundfos Chiller Pump RepairGrundfos Chiller Pump Repair
2 pumps, 1 duty and the other standby.One of these Grundfos pumps had failed previously leaving the standby to take up the slack.This is all well and good until the standby fails as well! These particular pumps are part of a chiller which was now out of service.The pumps where removed, completely overhauled (stator rewound, […]

Leisure Centre Pump refitLeisure Centre Pump refit
Replacing old obsolete pumps, especially when the modern alternatives are not a direct fit can be awkward to say the least. These 3 pumps were located about 8 feet below ground level and mounted on a concrete plinth.The first job was to remove the plastic pipework to allow us to remove the old units.New bases […]

Worn gearbox gearsWorn gearbox gears
Quite often we get specially designed gearbox units in for repair.Often, the gears are stripped as you can see in the images. The original unit is obsolete, a replacement gearbox will not fit and there are no spare parts available.As well as reproducing output shafts, we can also have gears remanufactured to original specification. The […]

42kw DC electric motor repair42kw DC electric motor repair
Recently had this 42Kw DC electric motor in for repair, as you can see the commutator is in extremely poor condition, the armature needed a rewind as did the field coils. This customers electric motor is now up and running- armature skimmed and rewound to spec.